news 03 June 2019

Energy rehabilitation of almost zero consumption housing

Energy rehabilitation of housing

One of the major challenges in the future of construction is the energy rehabilitation of the existing real estate stock. The 2030 horizon of the European Union in the framework on climate and energy aims to drastically reduce greenhouse gas emissions, incorporate renewable energies and improve energy efficiency. If we take into account that one of the sectors that most demand energy is residential buildings and that a large part of our cities are made up of buildings erected with regulations that hardly affected energy saving issues, it becomes clear that the rehabilitation energy is going to go to become a priority issue if the proposed objectives are truly to

be achieved.

An example of the type of intervention that should be carried out could be the case that we are going to explain below. It is the rehabilitation of a single-family house between medianeras from 1936, which is located in a consolidated urban environment with higher buildings. Customers did not demand a house with low energy demand, but with great insulation against noise. Faced with this request, it was proposed to the developer to focus on energy efficiency in the rehabilitation, until obtaining a building with almost zero energy consumption, since the increase in the quality of the construction to achieve such high energy efficiency entails the obtaining of high performance related to comfort, and among which is

good insulation against noise.

To achieve this goal, it was decided to carry out a rehabilitation that met the construction criteria of the Passivhaus standard.

The Passivhaus is a building standard that comes from Germany, which is performance-oriented, and which regulates and determines methods for the control and verification of your requirements, without requiring specific typological or constructive solutions. It is based on compliance with 5 basic principles that have a direct impact on reducing energy demand, increasing construction quality and comfort. The Passivhaus standard prioritizes the design and construction of passive buildings, so that a priori the active means used in their air conditioning are minimal. The five principles on which Passivhaus buildings are

based are:
  • Great thermal insulation, which protects from both cold and heat. Insulation reduces energy demand and improves comfort in indoor spaces.
  • Carpentry and high performance glass. This point is of vital importance since the exterior carpentry is the weakest element of the building envelope from the thermal point of view.
  • It requires the creation of a continuous air tightness band that prevents uncontrolled infiltrations through the building elements. The creation of the sealing strip assumes, among other things, the absence of air currents and contributes to the improvement of the interior acoustics. To verify the tightness, a pressure test is performed that allows the time of renewal to be measured. In Passivhaus buildings renovations hours should not exceed 0.63, while in conventional housing they are usually between 6-16 renovations/hour
  • .
  • Mechanical ventilation. Thanks to them, a high quality of indoor air is achieved because it avoids CO 2 concentrations, and because they have filters through which the air that enters from the outside passes, and which retain polluting particles, pollen, suspended particles, etc. It is advisable that the ventilation machines are double-flow with heat recuperator
  • .
  • Thermal bridges. Their control reduces energy losses through them. It also prevents the appearance of pathologies due to superficial condensations
.

Other aspects that this building standard also takes into account are sun protection to avoid overheating in summer; and the orientation of the building, which helps optimize the energy gains offered by the sun.

Compliance with these principles makes it possible to reach the performance limits set by the Passivhaus building standard, which are:

  • The heating demand must be less than 15 kWh/m 2 year or the heating load must be less than 10 W/m 2. This means a reduction in heating consumption of up to 90% compared to a traditional construction. For a house of 100 m 2, the power of a hair dryer would be enough to be able to heat it.
  • The demand for cooling and dehumidification must be less than 20 kWh/m 2 year or the cooling load must be less than 10 W/m 2. This means a reduction in cooling consumption of up to 90% compared to a traditional construction.
  • The frequency of overheating, that is, the time that the house can be above 25ºC, must be less than 10%.
  • The frequency of excessive high humidity, that is, the water content of the air is above 12 g/kg is less than 20%.
  • The pressure test at 50 pascals, blowerdoor, should give a result of less than 0.63 renewals/hour.
  • The primary non-renewable energy demand of the building must be below 120 kWh/m 2 year. In other words, the energy efficiency of all electrical appliances involved in consumption is evaluated

These values are independent of the climate.

The building standard has a retrofit version called Passivhaus Enerphit. The criteria are slightly less demanding than those of the Passivhaus standard applied in new construction since it takes into account that the intervention is carried out on a pre-existing building and there are certain parameters that cannot be

altered or modified.

Therefore, in the case at hand, the rehabilitation was planned to meet the requirements of the Passivhaus Enerphit standard.

The approximate area of the house to be rehabilitated was 140 m 2. It is a building between medianeras and consists of ground and first floor. A previous energy audit was carried out to know the state from which we were leaving so that we could establish a comparison after carrying out the rehabilitation. This comparison also made it possible to calculate the amortization period that was to be obtained from the small cost overrun that would entail complying with the Passivhaus standard.

The audit on the current state showed that the energy demand of the pre-existing housing reached 179 kWh/m 2 year. That is, in order to be able to heat the house, a heating power of about 14 kW would be necessary. For refrigeration, the demand amounted to 103 kWh/m 2 year. That is, that the house would need about 15 kW. These results are the consequence of having an enclosure without any type of insulation, simple glass wooden windows with blinds and no type of air conditioning system

.

After the analysis of the initial situation, it was decided to incorporate insulation of the entire building envelope, including the medians and the floor; the joinery was changed to another of high quality PVC with triple glazing with solar control sheets and low emissivity; a sealing band was created (which also acted as a vapor barrier) that would limit uncontrolled air infiltrations; elements of sun protection in summer for the windows, and a double-flow mechanical ventilation system was designed, that is, with recuperator of heat. This implies that the demand for heating became 13 kW/m 2 year; that is, the heating consumption of the house was reduced by about 90%; for cooling the energy demand became 12 kW/m 2 year, that is, the energy consumption in the summer period was reduced by more than 90%. This means a reduction of around 89% of CO 2 emissions (kg/m 2 year)

.

Taking an average price of €0.12 per kWh, we obtain that to maintain the house once rehabilitated in comfort temperature throughout the year it will take about 402€; while in the original state we would have needed about 4534.5€, this represents a saving of 91% of the annual energy expenditure in the house. With these figures, we obtain an amortization of the extra costs involved in the rehabilitation following the criteria of the Passivhaus Enerphit Institute

around 5 years.

The results not only show very high percentages in energy savings, but also in a very considerable reduction in greenhouse gas emissions. In addition, the incorporation of renewable energies in any building with such low energy demands means being able to carry out constructions with a positive energy balance, that is, that consume less energy than

they generate.

In short, and thanks to the proposed rehabilitation, a house that is almost a hundred years old will have features that not even 10% of the existing buildings have, going on to have the characteristics that will be required for all homes built from the year 2020.

Elena Fortes Archer

Architect

Passive house designer